Bit2:
Trace of warm start and connection cancelation in_N_SIEMDOMAINSEQ_MPF
Bit4:
Additional information about the PDUs sent is to be entered in _N_SIEMDOMAINSEQ_MPF
for upload
Bit5:
Additional information about the PDUs received is to be entered in
_N_SIEMDOMAINSEQ_MPF for upload
11297 PROTOC_IPOCYCLE_CONTROL N01 -
- Prevent overrun of IPO time level BYTE PowerOn
-
808d-me42 10 1, 1, 1, 1, 1, 1, 1, 1... 0 1 0/0
808d-me62 10 1, 1, 1, 1, 1, 1, 1, 1... 0 1 0/0
808d-te42 10 1, 1, 1, 1, 1, 1, 1, 1... 0 1 0/0
808d-te62 10 1, 1, 1, 1, 1, 1, 1, 1... 0 1 0/0
808d-mte40 10 1, 1, 1, 1, 1, 1, 1, 1... 0 1 1/1
808d-mte60 10 1, 1, 1, 1, 1, 1, 1, 1... 0 1 1/1
Description: Setting whether an overflow of the time level is to be prevented during the recording
of data in the time level of the IPO.
If applicable, data sets are discarded when the function is active, and are not entered
in the log file in order to prevent an impending overflow of the IPO time level.
This may mean that data sets are also then lost if a level overflow would not yet have
occurred with the function inactive.
The individual values apply to the users of the logging function, which are assigned
the following functions:
0: Reserved for system functions: simultaneous recording, simulation, synchronized
action analysis
1: Reserved for system functions: determining program runtimes, multi-step editor
2: Reserved for OEM applications
3: Reserved for OEM applications
4: Reserved for OEM applications
5: Reserved for system functions: trace
6: Reserved for system functions: trace
7: Reserved for system functions: trace
8: Reserved for system functions: trace
9: Reserved for system functions: action log
11298 PROTOC_PREPTIME_CONTROL N01 -
- Interruption time prep time level in seconds. DOUBLE PowerOn
-
808d-me42 10 1.0, 1.0, 1.0, 1.0, 1.0,
1.0, 1.0, 1.0...
- - 0/0
808d-me62 10 1.0, 1.0, 1.0, 1.0, 1.0,
1.0, 1.0, 1.0...
- - 0/0
808d-te42 10 1.0, 1.0, 1.0, 1.0, 1.0,
1.0, 1.0, 1.0...
- - 0/0
808d-te62 10 1.0, 1.0, 1.0, 1.0, 1.0,
1.0, 1.0, 1.0...
- - 0/0
Machine data
3.2 General machine data
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 65