EasyManua.ls Logo

Siemens SINUMERIK 808D ADVANCED - Page 175

Siemens SINUMERIK 808D ADVANCED
498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
175
Machine data
2.3 Channel-specific machine data
Description: Timers are provided as system variables under the function program runtime.
While the NCK-specific timers are always activated (for time measurements
since the last control power on), the channel-specific timers have to be
started via this machine data.
Meaning:
Bit 0 = 0
No measurement of total operating time for any part program
Bit 0 = 1
Measurement of total operating time is active for all part programs
($AC_OPERATING_TIME)
Bit 1 = 0
No measurement of current program runtime
Bit 1 = 1
Measurement of current program runtime is active ($AC_CYCLE_TIME)
Bit 2 = 0
No measurement of tool operating time
Bit 2 = 1
Measurement of tool operating time is active ($AC_CUTTING_TIME)
Bit 3
Reserved
Bits 4,5 only when bit 0, 1, 2 = 1:
Bit 4 = 0 No measurement with active dry run feed
Bit 4 = 1 Measurement also with active dry run feed
Bit 5 = 0 No measurement with program test
Bit 5 = 1 Measurement also with program test
Bit 6 only when Bit 1 = 1:
Bit 6 = 0
Delete $AC_CYCLE_TIME also with start by ASUB and PROG_EVENTs
Bit 6 = 1
$AC_CYCLE_TIME is not deleted on start by ASUB and PROG_EVENTs.
Bit 7 only when bit 2 = 1:
Bit 7 = 0 $AC_CUTTING_TIME counts only with active tool
Bit 7 = 1 $AC_CUTTING_TIME counts irrespective of tool
Bits 8 only when bit 1 = 1
Bit 8 = 0
$AC_CYCLE_TIME is not deleted on jumping to program start with GOTOS
Bit 8 = 1
$AC_CYCLE_TIME is deleted on jumping to program start with GOTOS.
Bit 9 only when bits 0, 1 = 1:
Bit 9 = 0
$AC_OPERATING_TIME, $AC_CYCLE_TIME: No measurement with override = 0.
Bit 9 = 1
$AC_OPERATING_TIME, $AC_CYCLE_TIME: Measurement also with override = 0.
Bits 10 to 31
27860 PROCESSTIMER_MODE C09 K1
- Activation and impact of program runtime measurement DWORD Reset
-
- - 0x177 0 0x7FF 1/1