Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
247
Machine data
2.4 Axis-specific machine data
Description: If the machine axis travels a maximum distance defined in MD34030
$MA_REFP_MAX_CAM_DIST from the starting position in the direction of the ref-
erence cam, without reaching the reference cam (NC/PLC interface signal
DB380x DBX1000.7 (Reference point approach delay) is reset), the axis stops
and alarm 20000 "Reference cam not reached" is output.
Irrelevant to:
Linear measuring systems with distance-coded reference marks
34030 REFP_MAX_CAM_DIST A03, A11 G1,R1
mm, degrees Maximum distance to reference cam DOUBLE Reset
-
- - 10000.0 0.0 - 2/2
Siemens Controls