Machine data
2.4 Axis-specific machine data
Parameter Manual
268
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Description:
The maximum speed of the current gear stage is configured in MD35135
$MA_GEAR_STEP_PC_MAX_VELO_LIMIT with position control active. The speed set-
points generated taking the override into account are limited to this speed.
If a value of 0 is set (default), 90% of the value from MD35130
$MA_GEAR_STEP_MAX_VELO_LIMIT will become the maximum speed with position con-
trol active.
Note:
• The configured speed cannot exceed the value from MD35100
$MA_SPIND_VELO_LIMIT.
• The NC/PLC interface signal "Setpoint speed limited" is set to indicate
that the speed is being limited.
• The maximum speed entered here has no effect on the automatic gear stage
selection M40 S..
• The upper switching threshold for the automatic gear stage selection M40
is configured in MD35110 $MA_GEAR_STEP_MAX_VELO.
Related to:
MD35130 $MA_GEAR_STEP_MAX_VELO_LIMIT (maximum speed of the gear stage with
spee control)
MD35140 $MA_GEAR_STEP_MIN_VELO_LIMIT (minimum speed of the gear stage)
MD35010 $MA_GEAR_STEP_CHANGE_ENABLE (gear stage selection is possible)
MD35110 $MA_GEAR_STEP_MAX_VELO (max. speed for automatic gear stage selection
M40)
MD35120 $MA_GEAR_STEP_MIN_VELO (min. speed for automatic gear stage selection
M40)
35135 GEAR_STEP_PC_MAX_VELO_LIMIT A06, A11, A04 S1
rev/min Maximum speed of the gear stage with position control DOUBLE NEW CONF
CTEQ
- 6 0., 0., 0., 0., 0., 0. 0 - 2/2