04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–198
SINUMERIK 840C / SIMODRIVE 611–D (DA)
300705 Position controller clock pulse invalid POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
A position controller clock cycle has been set at the NC that is not allowed for the drive
Change position controller clock cycle at the NC
Applies as from SW 3
300706 Monitoring clock pulse invalid POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
Monitoring clock pulse MD 1002 is invalid
Change monitoring clock cycle
Applies as from SW 3
300707 Drive basic clock pulse axially not equal POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
On 2-axis modules, the drive basic clock cycle must be identical for both axes.
On 2-axis modules, the drive basic clock pulse must be set to be identical for both axes.
Applies as from SW 3
300708 Current controller clock cycle axially not equal POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
On 2-axis modules, the current controller clock pulse MD 1000 must be identical for both axes.
Set the current controller clock cycle to be identical for both axes.
Applies as from SW 3
300709 Speed controller clock pulse axially not equal POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
On 2-axis modules, the speed controller clock pulse MD 1001 must be identical for both axes.
Set speed controller clock pulse to be identical for both axes.
Applies as from SW 3
300710 Position controller clock pulse axially not equal POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
On 2-axis modules, the position controller clock pulse must be identical for both axes.
Set the position controller clock pulse to be identical for both axes.
Applies as from SW 3
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description