04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
2–6
SINUMERIK 840C / SIMODRIVE 611D (DA)
HLL_MACRO function
DC Core to be called not available or cannot be called by HLL
HLL_STOP function
DD Sytem STOP by HLL user *)
HLL_S5 function
DE Unknown pseudo parameter in STACK
DF S5 block called not available
E0 S5 block not in line with paragraph
E1 Block called is not a S5 block
Other operational and user errors
F7 M decoding: byte number for DB30>63
F8 PROTES system error: error with P link *)
F9 Interrupts from interrupt-generating I/O devices not acknowledged by OB2
Errors in addressing decoding data blocks
FA Decoding data block not available
FB Data block word length without header not divisible by 3
FC Wrong number of decoding units
FD Decoding data block too short
FE Assignment list DB99 not available or too short
Error message with function macros
FF Group error with function macros *)
Display of individual errors with function macros is via ACCU1 and ACCU2. The ACCUs
can be read out at the programmer via OUTPUT ISTACK.
For more details on errors see FB descriptions.
2 Diagnostics on the PLC
2.1 Error numbers (ACCU 3 high byte, DB 1 DW 160)
*) Additional information is given on this error in additional fields (see Section 2.2)

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals