EasyManuals Logo

Siemens SINUMERIK 840C Diagnostics Guide

Siemens SINUMERIK 840C
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #209 background imageLoading...
Page #209 background image
04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–201
SINUMERIK 840C / SIMODRIVE 611D (DA)
300721 I0 motor > i-rated motor POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
Motor no-load current (MD 1136) is greater than the rated current (MD 1103) of the motor.
S Change motor data
S Save BOOT drive
S Repeat ramp-up
Applies for SW 3 only
300722 I0 motor > I-rated power section POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
Connected motor too large for power section being used (continuous current MD 1108) because of its no-load
current (MD 1136).
Change power section or motor
Applies for SW 3 only
300723 STS configuration axially unequal POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
On 2-axis modules, the configuration of the control set MD 1003 must be identical for both axes.
Make the configuration of the control set identical for both axes.
Applies as from SW 3
300724 Invalid pole pair number POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
FDD: MD 1112 is not correct.
MSD: MD 1134 or MD 1400 is not correct.
Eliminate error on inputting the above machine data.
Applies as from SW 4
300725 Number of encoder marks = 0 POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
The number of encoder marks MD 1005 has the value 0.
Eliminate error when entering the number of encoder marks MD 1005.
Applies as from SW 3
300726 Voltage constant = 0 POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
The voltage constant MD 1114 has a value less than or equal to zero.
Eliminate error on inputting the voltage constant MD 1114.
Applies as from SW 4
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals