04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–211
SINUMERIK 840C / SIMODRIVE 611–D (DA)
300762 Emergency retract/generator active Reset key
300862
Cyclic after control power up
for MSD:
S Pulse suppression, motor runs down
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
for FDD:
S Controllers are disabled, motor is braked
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
Response via MD 1613.0 can be configured as from drive SW 2.
Alarm output can be activated via MD 1012.4 as from V. 5.2 (611D: SW 3).
S MD 1012.4 = 0: 300762
S MD 1012.4 = 1: 300862
Emergency retraction or generator is already active.
Check parameterization/machine data.
Applies as from SW 4
300763 Generator/emergency retraction mode invalid Reset key
300863
Cyclic
for MSD:
S Pulse suppression, motor runs down
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
for FDD:
S Controllers are disabled, motor is braked
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
Response via MD 1613.0 can be configured as from drive SW 2.
Alarm output can be activated via MD 1012.4 as from V. 5.2 (611D: SW 3).
S MD 1012.4 = 0: 300763
S MD 1012.4 = 1: 300863
Value given by the NC via a G command must be in the range 0 ... 7.
Check parameterization (G command in the NC).
Applies as from SW 4
300764 No emergency retraction/generator mode possible Reset key
300864
Cyclic
for MSD:
S Pulse suppression, motor runs down
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
for FDD:
S Controllers are disabled, motor is braked
S SIMODRIVE_READY and DRIVE_READY are cancelled.
S Reset error
Response via MD 1613.0 can be configured as from drive SW 2.
Alarm output can be activated via MD 1012.4 as from V. 5.2 (611D: SW 3).
S MD 1012.4 = 0: 300764
S MD 1012.4 = 1: 300864
Emergency retraction/generator mode is possible only with active d.c. link measurement (MD 1161 = 0) in an old
hardware version, no d.c. link measurement is possible and therefore the error message 300765 might also be
issued if in an old hardware version MD 1161 is set to zero.
Enter the value zero into machine data MD 1161 or order new hardware version (hardware components: drive
control with Order No. 6SN1 118–0Dx1x–0AA0).
Applies as from SW 4
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description
07/97