04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–14
SINUMERIK 840C / SIMODRIVE 611D (DA)
47 Wrong TO assignment lists POWER ON
S At POWER ON after modifying machine data
S Interlocking of NC START
S Value of machine data 210, Number of TO areas, is greater than 4
S TO start numbers in NC MD211 to 214 have not been entered in ascending order
S Input value in channel-specific NC MD 1040 to 1043 is greater than the number of TO areas under MD 210 or
is specified as 0 in the TO area
S Correct machine data
S Where appropriate format user memory if machine data were input correctly or format the TO data in General
Reset mode
S POWER ON
48 Data link to PLC not ready POWER ON
S Interlocking of NC START
S Interlocking of NC Ready relay
S Interlocking of Mode Group Ready
S Machining stops
During the start-up synchronization or data exchange between interface-CPU (IFC) and PLC CPU an error was
established, leading to the alarm. Data exchange between NC and PLC is still possible but the link to the pro-
grammer via the interface is not possible.
Error fine coding can give information on further error sources; in addition, check whether alarm 43 is present.
Applies up to SW 2 only
49 NC in general reset POWER ON
POWER ON
None
The software has recognized that the control is in general reset mode.
Leave general reset mode
50 Flex. memory incorrectly configured POWER ON
50 Insufficient memory for block buffer POWER ON
On pressing NC Start
Interlocking of machining
Interlocking of NC Start
1. The channel-specific machine data 6100* that defines the number of block buffers in a channel is not in the
permissible range.
2. No memory has been made available (MD 60014) for loading of drive software (MD 60003 or 60004).
Check and correct the values of the machine data.
Alarm Insufficient memory for block buffer (with SW 4 and higher)
Alarm Flex. memory incorrectly configured (with SW 5.4 and higher)
57 Drive link failure POWER ON
Cyclic
Interlocking of NC Ready, NC Start, Mode Group Ready, NC Stop
Internal software error or ring programming for GI or gantry axes.
S Eliminate ring programming for GI or gantry axes
S Notify service
Scan
Effect
Explanation
Remedy
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
1 Alarms
1.5.1 Alarm description
07/97

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals