04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–217
SINUMERIK 840C / SIMODRIVE 611D (DA)
300783 Rotor resistance invalid Reset key
Power–up and cyclic
MSD only:
Pulse suppression, motor coasts down
SIMODRIVE_READY and DRIVE_READY are canceled.
The rotor resistance is less than or equal to zero or a format overflow has occurred.
The following machine data may have an incorrect value:
Speed controller cycle MD 1001
Motor rated frequency MD 1134
Rotor resistance cold MD 1138
Stator leakage reactance MD 1139
Rotor leakage reactance MD 1140.
Applies as from SW 6
300784 Motor no-load voltage invalid Reset key
Power–up and cyclic
MSD only:
Pulse suppression, motor coasts down
SIMODRIVE_READY and DRIVE_READY are canceled.
Error in noload voltage (MD 1135):
MD 1135 x 0 or
MD 1135 > MD 1132 or
MD 1135 x MD 1142 / MD 1400 + Vpre>450 V
With
Vpre=0.181 x MD 1136 x MD 1142 x MD 1119
MD 1132: Rated motor voltage
MD 1400: Rated motor speed
MD 1142: Threshold speed field weakening
MD 1136: Noload motor current
MD 1119: Inductance series reactor
Correct error when entering
Rated motor voltage MD 1132 or:
Noload motor voltage MD 1135 or
Rated motor speed MD 1400 or
Rotor resistance cold MD 1138
Threshold speed field weakening MD 1142 or
Noload motor current MD 1136.
Applies as from SW 6
300785 Motor no-load current x 0 Reset key
Power–up and cyclic
MSD only:
Pulse suppression, motor coasts down
SIMODRIVE_READY and DRIVE_READY are canceled.
Motor noload current MD 1136 is smaller than or equal to zero.
Correct the error when entering the motor noload current MD 1136.
Applies as from SW 6
300786 Field weakening speed x 0 Reset key
Power–up and cyclic
MSD only:
Pulse suppression, motor coasts down
SIMODRIVE_READY and DRIVE_READY are canceled.
Field weakening speed MD 1142 is smaller than or equal to zero.
Correct the error when entering the field weakening speed MD 1142.
Applies as from SW 6
Scan
Effect