EasyManuals Logo

Siemens SINUMERIK 840C Diagnostics Guide

Siemens SINUMERIK 840C
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #82 background imageLoading...
Page #82 background image
04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–74
SINUMERIK 840C / SIMODRIVE 611D (DA)
1300* Progr. axis is not a rotary axis CANCEL
When executing AUTOMATIC, MDA and TEACH IN
S Interlocking of NC START
S Machining stop
G[...]103, G[...]104, G[...]105, G[...]119, G195, G295 not programmed in connection with a rotary axis.
Correct the block!
Applies as from SW 4; alarm is channel-specific and block-specific!
1304* Axis turning endlessly Reset key
On block search with calculation
S Cancellation of the block search
An endlessly rotating rotary axis is programmed as contouring axis although the axis is still rotating endlessly.
Stop the endlessly rotating rotary axis and start the block search again.
Applies as from SW 4; alarm is channel-specific and block-specific!
1308* Error in progr. of sim. axis Reset key
When executing a part program
S Machining abort
The Endlessly rotating rotary axis is programmed with G[..]119P[..].. without the endless rotation being switched
on.
Correct the block!
Applies as from SW 4; alarm is channel-specific and block-specific!
1312* Error in progr. of sim. axis CANCEL
When executing a part program
S Machining abort
The Endlessly rotating rotary axis has been incorrectly programmed.
Correct the block!
Applies as from SW 4; alarm is channel-specific and block-specific!
1316* Programmed position behind SW limit switch Reset key
When executing a part program
Processing stops at indicated block.
The programmed end point of the displayed axis (incl. the active offsets) lies behind the software limit switch.
S Correct program
S Check MD 1st and 2nd software limit switch plus/minus
S Check PLC interface signal 2nd software limit switch active
Alarm is displayed axis-specifically, for the block and channel in question.
Alarm applies as from SW 5
1320* Axis not in C axis mode CANCEL
When traversing a C axis that is in spindle mode.
Axis is not traversed.
A C axis has been programmed in spindle mode.
The alarm is only output if MD 5025.5 is set.
Switch C axis to C axis mode.
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
1 Alarms
1.5.1 Alarm description
07/9707/97

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals