04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–86
SINUMERIK 840C / SIMODRIVE 611–D (DA)
2029* Drive fault Reset key
S 611–D alarm 300100 “Drive link off”
S Power On / Reset alarms (ZK1) from 611–D
S Interlocking of NC START
S Interlocking of Mode Group Ready
S Setpoint 0
S Setpoint enable is removed after the time set in NC MD “Switch off delay servo enable” (not with alarm “Drive
link off”)
S Follow up mode
S 611–D status signals “Drive ready” and “Drive connected” are reset
S Further detailed information on the cause in MMC diagnosis display
Applies as from SW 3
2030* Spindle speed too high Reset key
Only when NC MD “Encoder available” is set
S Machining stops
S Interlocking of NC START
S Interlocking of Mode Group Ready
The spindle speed is higher than defined in the machine data or setting data.
S Program a smaller S value
S NC MD “Max spindle speed for 1st to 8th gearing”
S NC MD “Tolerance band of max. spindle speed”
S NC MD “Max. spindle speed”
S Check PLC gear speed
S Check G92 S... at “v = constant”
S Check setting data of spindle speed limitation
S Program G26 S...
2032* Output not available POWER ON
When setpoint incorrectly assigned
S Interlocking of NC START
S Interlocking of Mode Group Ready
S Interlocking of NC Ready
S Setpoint 0
S No servo enable
S Follow-up mode
A digital setpoint output that does not exist has been assigned
Check the setpoint output machine data
Applies as from SW 3
2033* Drive fault POWER ON
S 611–D alarms
– Drive configuration description incorrect
–– Drive number
–– Drive type (FDD/MSD)
–– Module type (single-axis/double-axis module)
– Ramp up error (error during 611–D rump-up, error during data matching)
– Transmission line fault (CRC, bus timeout)
S Interlocking of NC START
S Interlocking of Mode Group Ready
S Interlocking of NC Ready
S Setpoint 0
S Servo enable removed after time set in NC MD “Switchoff delay servo enable” has passed
S Follow-up mode
Additional detailed information about the cause is given in the MMC diagnosis display