04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–86
SINUMERIK 840C / SIMODRIVE 611D (DA)
2029* Drive fault Reset key
S 611–D alarm 300100 Drive link off
S Power On / Reset alarms (ZK1) from 611–D
S Interlocking of NC START
S Interlocking of Mode Group Ready
S Setpoint 0
S Setpoint enable is removed after the time set in NC MD Switch off delay servo enable (not with alarm Drive
link off”)
S Follow up mode
S 611–D status signals Drive ready and Drive connected are reset
S Further detailed information on the cause in MMC diagnosis display
Applies as from SW 3
2030* Spindle speed too high Reset key
Only when NC MD Encoder available is set
S Machining stops
S Interlocking of NC START
S Interlocking of Mode Group Ready
The spindle speed is higher than defined in the machine data or setting data.
S Program a smaller S value
S NC MD Max spindle speed for 1st to 8th gearing
S NC MD Tolerance band of max. spindle speed
S NC MD Max. spindle speed
S Check PLC gear speed
S Check G92 S... at v = constant
S Check setting data of spindle speed limitation
S Program G26 S...
2032* Output not available POWER ON
When setpoint incorrectly assigned
S Interlocking of NC START
S Interlocking of Mode Group Ready
S Interlocking of NC Ready
S Setpoint 0
S No servo enable
S Follow-up mode
A digital setpoint output that does not exist has been assigned
Check the setpoint output machine data
Applies as from SW 3
2033* Drive fault POWER ON
S 611–D alarms
Drive configuration description incorrect
–– Drive number
–– Drive type (FDD/MSD)
–– Module type (single-axis/double-axis module)
Ramp up error (error during 611D rump-up, error during data matching)
Transmission line fault (CRC, bus timeout)
S Interlocking of NC START
S Interlocking of Mode Group Ready
S Interlocking of NC Ready
S Setpoint 0
S Servo enable removed after time set in NC MD Switchoff delay servo enable has passed
S Follow-up mode
Additional detailed information about the cause is given in the MMC diagnosis display
Applies as from SW 3
Scan
Remedy
Note
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Remedy
Note
1 Alarms
1.5.1 Alarm description

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals