04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–90
SINUMERIK 840C / SIMODRIVE 611–D (DA)
2075* GI configuration not allowed Reset key
When programming DEFINE CONFIGURATION with G function (from NCK).
S Command is not executed
S Interlocking of NC START
S NC STOP
S Channel stopped: JOG mode still possible
Possible causes:
S Do leading and following axes have a position measuring system (encoders)?
S Is the following axis linked to itself as a leading axis?
S Can the axis be a following axis (MD 1844*)?
S Link structure switchover not permissible (MD 1844*)
S Link type for the LA/LS not allowed (MD 1456*/496*)?
S The following axes must always be real available axes, i.e. a measuring circuit (POS encoder) must be defi-
ned. A measuring circuit must be defined for leading axes/spindles with link structure K2 (actual position link).
S Leading axes/spindles and following axis are not in the same mode group.
S Not exactly one leading spindle defined for following spindle.
S One of the axes in the GI grouping is a fictitious transformation axis.
S No synchronous positions have been defined for on-the-fly synchronization.
Check configuration
Applies as from SW 3
2076* Following spindle not defined Reset key
When programming a spindle as a following spindle which has not been defined as such (from NCK).
S G command is not executed
S Interlocking of NC START
S NC STOP
S Channel stopped: JOG mode still possible
A GI grouping with the stated axis as a following spindle does not exist.
Correct input.
Applies as from SW 3
2077* Spindle not in spindle mode Reset key
The programmed following spindle has a C axis which has been selected for C axis mode.
S Command is not executed
S Interlocking of NC START
S NC STOP
S Channel stopped: JOG mode still possible
When programming a following spindle which is assigned to a C axis, this C axis must be in spindle mode.
This is not necessary with G401, but a GI grouping must not be defined for the C axis at the same time.
Correct mode/input.
2078* Leading spindle not defined Reset key
When programming a spindle as a leading spindle or an axis as a leading axis which have not been defined as
such (from NCK).
S G command is not executed
S Interlocking of NC START
S NC STOP
S Stop channel: JOG mode is still possible
A GI grouping with the stated axis as a leading axis does not exist
Correct input.