7SJ61/62/63 6MD63 - Modbus
C53000-L1840-C001-01
v
Table of contents
1 Bus specific parameters ................................................................................................1-1
2 Supported Modbus functions........................................................................................2-1
3 Exception responses of the Modbus slave..................................................................3-1
4 Annunciations to the Modbus master ..........................................................................4-1
5 Data type definitions ......................................................................................................5-1
5.1 Single command (SC) / Single-point indiation (SP) .............................................5-2
5.2 Double command (DC) / Double-point indication (DP)........................................5-2
5.3 Measured value (signed integer) .........................................................................5-3
5.4 Metered measurand (unsigned long)...................................................................5-3
6 Modbus register map .....................................................................................................6-1
6.1 Explanation ..........................................................................................................6-1
6.2 Notes for parametrization in DIGSI......................................................................6-2
6.3 Coil status registers (0X references) ...................................................................6-3
6.3.1 Register addresses 00001 to 00018:
Double commands...............................................................................................6-3
6.3.2 Register addresses 00033 to 00054:
Single commands ................................................................................................6-4
6.3.3 Register addresses 00065 to 00071:
Internal commands ..............................................................................................6-5
6.3.4 Register addresses 00081 to 0096:
Application logic CFC...........................................................................................6-6
6.3.5 Register addresses 00257 to 00264:
Exception flags.....................................................................................................6-8
6.4 Input status registers (1X references)..................................................................6-9
6.4.1 Register addresses 10001 to 10037:
Input channels with allocation to the binary inputs...............................................6-9
6.4.2 Register addresses 10049 to 10064:
Application logic CFC.........................................................................................6-10
6.4.3 Register addresses 10065 to 10089:
Automatic recloser status ..................................................................................6-11
6.4.4 Register addresses 10097 to 10137:
Time overcurrent protection...............................................................................6-12