Table of contents
ix
SIPROTEC Modbus - Bus mapping
C53000-L1840-C009-03
3.2.5 Registers 10024 to 10026: Thermal overload protection..................................................... 3-5
3.2.6 Registers 10027 to 10031: Unbalanced load protection...................................................... 3-5
3.2.7 Registers 10032 to 10036: Sensitive ground fault protection.............................................. 3-5
3.2.8 Registers 10037 to 10040: Stator ground fault protection................................................... 3-6
3.2.9 Registers 10041 to 10042: Stator ground fault protection with 3
rd
harmonic ...................... 3-6
3.2.10 Registers 10043 to 10046: Overvoltage protection ............................................................. 3-6
3.2.11 Registers 10047 to 10050: Undervoltage protection........................................................... 3-6
3.2.12 Registers 10051 to 10058: Frequency protection................................................................ 3-7
3.2.13 Registers 10059 to 10063: Overexcitation protection.......................................................... 3-7
3.2.14 Registers 10064 to 10066: Reverse power protection ........................................................ 3-7
3.2.15 Registers 10067 to 10070: Forward power supervision ...................................................... 3-7
3.2.16 Register 10071: Fuse Failure Monitor ................................................................................. 3-8
3.2.17 Registers 10072 to 10077: Underexcitation protection........................................................ 3-8
3.2.18 Registers 10078 to 10079: Circuit breaker failure protection .............................................. 3-8
3.2.19 Registers 10080 to 10087: Impedance protection............................................................... 3-8
3.2.20 Registers 10088 to 10091: Binary inputs............................................................................. 3-9
3.2.21 Registers 10092 to 10093: Inadvertent energisation protection.......................................... 3-9
3.2.22 Register 10094: Trip coil monitor.........................................................................................3-9
3.2.23 Registers 10095 to 10096: Inverse undervoltage protection............................................... 3-9
3.2.24 Registers 10097 to 10099: Startup supervision of motors................................................... 3-9
3.2.25 Register 10100: Startup counter for motors ...................................................................... 3-10
3.2.26 Registers 10101 to 10102: Rotor ground fault protection (R,fn)........................................ 3-10
3.2.27 Registers 10103 to 10104: DC voltage/current protection................................................. 3-10
3.2.28 Registers 10105 to 10108: State of the out-of-step protection.......................................... 3-10
3.2.29 Registers 10109 to 10115: Differential protection ............................................................. 3-10
3.2.30 Registers 10116 to 10117: Stator ground fault protection 100%....................................... 3-11
3.2.31 Registers 10118 to 10119: Rotor ground fault protection 1-3 Hz ...................................... 3-11
3.2.32 Registers 10120 to 10121: Restricted ground fault protection .......................................... 3-11
3.2.33 Registers 10122 to 10129: Fault indications of protection functions ................................. 3-11
3.3 Input registers (3X references).......................................................................................... 3-12
3.4 Holding registers (4X references)...................................................................................... 3-13
3.4.1 Registers 40001 to 40036: System information................................................................. 3-13
3.4.2 Registers 40065 to 40069: Time synchronization ............................................................. 3-13
3.4.3 Register 40129: Diagnosis ................................................................................................ 3-14
3.4.4 Registers 40201 to 40208: Metered measurands ............................................................. 3-15
3.4.5 Register 40251: Measured values in output direction ....................................................... 3-15
3.4.6 Registers 40301 to 40324: Statistic values ....................................................................... 3-16
3.4.7 Registers 40351 to 40410: Min/Max values of measured values...................................... 3-17
3.4.8 Registers 40601 to 40626: Event recorder (Sequence of Events).................................... 3-19
Glossary ............................................................................................................................................ 4-1
Index .................................................................................................................................................. 5-1