System overview
2.4 System data
Hydraulic Drive
System Manual, 04/2015, 6SL3097-4BA00-0BP1
33
Transport and storage conditions
Originally packaged modules
The following data applies to modules in their original packaging.
Table 2- 4 Climatic conditions
Temperature range
Upper temperature limit +55 °C
Relative air
No rain, no condensation, no spray water, no for-
mation of ice, no salt mist
5 ... 95 %
Condensation Regarding condensation, the following conditions
Seldom, brief, slight
Frequency of condensation Annual average: 3
Shortest sequence of condensation cycles
Temperature change
Environmental conditions
Relevant standards
● Contaminants: Class 3C1 according to EN 62477-1 or IEC 61800-2 draft (referred to
2013).
● It is only permissible to operate the device in rooms/areas with degree of pollution 2
(according to EN 61800-5-1).
● If the HLA module is operated in rooms/areas with levels of dust that could impair the
functionality, it must be operated in a cabinet with a heat exchanger or in a cabinet with a
suitable air intake.