Commissioning
4.17 Editing the valve characteristic
Hydraulic Drive
System Manual, 04/2015, 6SL3097-4BA00-0BP1
91
Further actions
Use the "Axis +" / "Axis -" softkeys to change to the next/previous axis.
Use the "Select axis >" softkey to open a dialog in order to select the axis from a list.
Use the "Select DDS" softkey to open a dialog to select the drive data set (DDS) whose
parameters are to be displayed in the list. You can also select the active drive data set in
this dialog.
The selected drive data set does not apply for the measurement of the characteristic. The
measurement is always performed with drive data set that is active in the drive at the time
of the measurement.
The drive data set to which the dialog refers is displayed at the far right of the window
title, e.g. DDS0.
Use the "Copy characteristic" softkey to open a dialog to select the drive data sets to
which the characteristic parameters are to be copied.
Use the "Back" softkey to return to the "Valve characteristics measurement" dialog.