Safety notes
2.2 Installation in hazardous area
SITRANS F M MAG 3100
Operating Instructions, 06/2010, A5E03005599-01
11
Table 2- 2 PED table key
EXD.PED Excluded from PED under SEP or LVD
PED Product covered by PED and only available as fully PED-conforming
PED* Product covered by PED but available as either conforming or non-conforming to
PED
N/A Size/pressure outside of PED scope or not available in the size range
N/A* DN1400-2000 only avalable non conforming to PED
CAUTION
All products sold outside of EU and EFTA are excluded from the Pressure Equipment
directive, also products sold into certain market sectors are excluded. These include
1. Meters used in networks for the supply, distribution and discharge of water.
2. Meters used in pipelines for the conveyance of any fluid from offshore to onshore.
3. Meters used in the extraction of petroleum or gas, including christmas tree and manifold
equipment.
4. Any meter mounted on a ship or mobile offshore platform.
2.2 Installation in hazardous area
WARNING
Equipment used in hazardous areas must be Ex-approved and marked accordingly. It is
required that the special conditions for safe use provided in the manual and in the Ex
certificate are followed!
Hazardous area approvals
The device is approved for use in hazardous area and has the following approvals:
MAG 3100 Ex DN 350-2000:
● II 2 GD Ex e ia IIC T3-T6 (MAG 3100 Ex remote mounted)
● II 2 (1) (2) GD Ex de [ia] ia [ib] IIC T3-T6 (MAG 3100 Ex compact mounted with MAG
6000 I Ex de)