Technical data
8.1 Cable data
SITRANS F M MAG 3100
Operating Instructions, 06/2010, A5E03005599-01
53
8.1 Cable data
Description
Cable for standard electrode or coil
Electrode cable, double shielded
Cable kit with standard coil cable and electrode cable double
shielded (also available as low noise cable for MAG 1100
sensor )
Standard applications
Table 8- 8 Technical data, standard application cables
Coil cable Standard electrode
cable
No. of conductors Basic data 2 3
Min. sqr. area 0.5 mm
2
0.2 mm
2
Shield Yes Yes
Max. capacita
nce N/A 350 pF/m
Media temperature:
< 100 °C 40 Ω N/A
Max. cable loop resistance
>
200 °C 6 Ω N/A
M20x1.5 gland - Cable ø 5 ... 13 mm (0.20 ... 0.51 inches) Cable glands on sensor
and transmitter
½ NPT gland - cable ø 5 ... 9 mm (0.20 ... 0.35 inches)
Special applications, e.g. low conductivity or electrical noise
Table 8- 9 Technical data, special application cables
Coil cable Special electrode cable
No. of conductors Basic data 3 3
Sqr. area 1.5 mm
2
0.25 mm
2
Shield Yes Double
Color code Brown, blue, black Brown, blue, black
Outside color Grey Grey
Ext. diameter 7.8 mm 8.1 mm
Conductor Flexible CU Flexible CU
Isolatio
n material PVC PVC