Technical data
8.3 Process fluid conductivity
SITRANS F M MAG 3100
Operating Instructions, 06/2010, A5E03005599-01
55
Table 8- 10 Metric measures (pressure in bar) - Sizes 25 mm, 40 mm and >300 mm
Flange
specifications
Flange rating Temperature (°C)
-5 10 50 90
PN 10 10.0 10.0 9.7 9.4
PN 16 16.0 16.0 15.5 15.1
EN 1092-1
PN 40 40.0 40.0 38.7 37.7
ANSI B16.5 150 lb 19.7 19.7 19.3 18.0
AWWA C-207 Class D 10.3 10.3 10.3 10.3
Table 8- 11 Imperial measures (pressure in psi) - Sizes 1", 1½" and >12"
Flange
specifications
Flange rating Temperature (°F)
23 50 120 200
PN 10 145 145 141 136
PN 16 232 232 225 219
EN 1092-1
PN 40 580 580 561 547
ANSI B16.5 150 lb 286 286 280 261
AWWA C-207 Class D 150 150 150 150l
8.3 Process fluid conductivity
Compact installation
Liquids with an electrical conductivity ≥ 5 μS/cm.
Remote installation
Standard cable
Cabel length
Conductivity
of medium
[µS/cm]
[m]
300
200
1005
300
200
100
5
150
600 900
[ft]
300

Related product manuals