Technical data
SITRANS F M MAG 3100
52 Operating Instructions, 06/2010, A5E03005599-01
Version MAG 3100 P MAG 3100 MAG 3100 HT
Ex approvals Ex sensor DN 15 ... 300:
ATEX 2GD Ex de ia IIC T3
- T6
IEC Ex de e ia IIC T3 - T6
FM Class 1 Div 1
FM Class 1 Zone 1
CSA Class 1 Zone 1
Standard sensors:
FM Class 1 Div 2
CSA Class 1, Div 2
Ex sensor DN 15 ... 300:
ATEX 2GD Ex de ia IIC T3
- T6
IEC Ex e ia IIC T3 - T6
FM Class 1 Div 1 (Only
compact mounted)
FM Class 1 Zone 1
CSA Class 1 Zone 1
DN 350 ... 2000:
Ex e ia IIC T4 - T6
FM Class 1 zone 1
CSA Class 1 zone 1
IEC Ex de ia IIC T3-T6
Ex tD A21 IP67
Standard sensors:
FM Class 1 Div 2
CSA Class 1, Div 2
Ex sensor DN 15 ... 300:
ATEX 2GD Ex de ia IIC T3
- T6
IEC Ex de ia IIC T3-T6
FM Class 1 zone 1
CSA Class 1 zone 1
Standard sensors:
FM Class 1 Div 2
CSA Class 1, Div 2
Drinking water approvals EPDM lining:
• WRAS (WRc, BS6920 cold
water, GB)
• NSF/ANSI Standard 61
(Cold water, US)
• ACS listed (F)
• DVGW W270 (D)
• Belgaqua (B)
• MCERTS (GB) (EPDM or
PTFE lining with AISI 316 or
Hastelloy electrodes)
Custody transfer (CT)
(≤ DN2000)
(only with MAG
5000/6000 CT)
Heat meter pattern approval:
OIML R 75 (Denmark)
Hot water pattern approval:
PTB (Germany)
Other media than water:
OIML R 117 (Denmark)
Cold water pattern approval:
DANAK
TS 22.36.001, PTB
(Denmark and Germany)
Heat meter pattern approval:
OIML R 75 (Denmark)
Hot water pattern approval:
PTB (Germany)
Other media than water
OIML R 117 (Denmark)
Heat meter pattern approval
OIML R 75 (Denmark)
Hot water pattern approval
PTB (Germany)
1) For sizes larger than 600 mm (24") in PN 16 PED conformity is available as a cost-added option. The basic unit will carry the LVD (Low Voltage Directive) and EMC approval.