EasyManua.ls Logo

Siemens SITRANS F MAG 6000 I - 2.3.3 FM Class I, II, III, Div 1 approval

Siemens SITRANS F MAG 6000 I
107 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety notes
2.3 Installation in hazardous area
MAG 6000 I / MAG 6000 I Ex de transmitter
Operating Instructions, 04/2016, A5E02083319-AG
17
2.3.2
FM/CSA Class I, Zone 1 approval
Compact and remote versions
FM: Class I, Zone 1 IIC
CSA: Class I, Zone 1 IIC, Zone 21
User I/O interface
Remote MAG 6000 I: Model 7ME693-2BA4/5
Compact:
MAG 6000 I with MAG 1100: Model 7ME6110-xxx2x-xD/E
MAG 6000 I with MAG 1100 F: Model 7ME6140-xxx2x-xD/E
MAG 6000 I with MAG 3100 series: Model 7ME63x0-xxxxx-xD/E
Passive current
(31, 32)
Active current
(31, 32)
Relay
(44, 45, 46)
Frequency/pulse
(56, 57)
Profi (FISCO)
(95, 96)
Digital input
(77, 78)
IIB/IIC
IIB
IIC
IIB/IIC
IIB/IIC
IIB/IIC
IIB/IIC
U
i
28 V DC
U
O
30 V DC
30 V DC
U
i
30 V DC
U
i
28 V DC
U
i
17.5 V DC
U
i
30 V DC
I
I
100 mA
I
O
87.8 mA
87.8 mA
I
I
200 mA
I
I
100 mA
I
I
380 mA
I
I
C
I
19.7 nF
C
O
557 nF
63 nF
C
I
7.5 nF
C
I
14.2 nF
C
I
0 nF
C
I
0 nF
L
I
36 µH
L
O
18.4 mH
4.6 mH
L
I
0 µH
L
I
36 µH
L
I
0 µH
L
I
0 µH
P
I
0.7 W
P
O
0.66 W
0.61 W
P
I
1.2 W
P
I
1.2 W
P
I
5.32 W
P
I
1.2 W

Table of Contents

Related product manuals