Technical data
11.1 Technical specifications
MAG 6000 I / MAG 6000 I Ex de transmitter
62 Operating Instructions, 04/2016, A5E02083319-AG
Technical specifications for MAG 6000 I standard and Ex version
Operation Standard version
-25 to +60 °C (-13 to +140 °F)
Ex version:
-25 to +60 °C (-13 to +140 °F)
Storage
-40 to +70 °C (-40 to +158 °F)
Mechanical load 18...1000 Hz random in x, y z, directions for 2
hours according to EN 60068-2-36 Transmitter:
1.14 grms
Protection degree IP67/NEMA 4X to IEC 60529 and DIN 40050
(1 mH
2
O 30 min.)
EMC performance
EN 61326
Display and keypad
Totalizer Two eight-digit counters for forward, net or
reverse flow
Display Background illumination with alphanumeric
text, 3 x 20 characters to indicate flow rate,
totalized values, settings and faults;
Reverse flow indicated by negative sign
Keypad Capacitive touch keypad with LED light for
feedback indication
Time constant
Time constant as current output time constant
Design
Enclosure material Die cast aluminum with corrosion-resistant
Basic Polyester power coating (min 60 µM)
Wall mounting bracket
Bracket enclosed for remote mounting
Dimensions
See dimensional drawings
Weight See dimensional drawings
Power supply
Standard version: 100 to 230 VAC, 47 to 63 Hz
20 to 27 VDC
Ex version: 100 to 230 VAC, 47 to 63 Hz
20 to 27 VDC
Power consumption
230 V AC: 21.5 VA
24 V DC: 12 W, I
N
= 380 mA, I
ST
= 1.5 A (10 ms)
Certificates and approvals
Standard version CE
C-tick
FM Class I, Div 2
FM Class I, Zone 2
CSA Class I, Div 2
CSA Class I, Zone 2
Ex version
Ex d e [ia] ia IIC T6 Gb Ex tD A21 IP67 T85°C
Ta -25°C to +60°C
FM Class I, II, III, Div 1
3)
FM Class I, Zone 1/21
CSA Class I, Zone 1/21

Table of Contents