SFIDK.PS.029.E5.02 / SW 2.01.0746
Displacement, menu 7.1.4.1.3 and menu 7.1.4.2.3 (to be changed for SONOKIT only)
Distance “h” between soundtrack and centre of pipe.
For SONOKIT: Data to be entered from “SENSOR GEOMETRY MEASURING REPORT”
If it is a 2-track SONOKIT, use same procedure for track 2.
For flow meters with sensors type SONO 3100 and SONO 3300 the factory settings should
not be changed.
Numbers of tracks, menu 7.2
The number of tracks preset from factory is shown. If necessary, this can be changed to 1,
2, 3 or 4-tracks.
For flow meters with sensors type SONO 3100 and SONO 3300 the factory settings should
not be changed.