4.4 Diagnostics Menu
Si-Ware Quick Start
Programming Manual, 10/2011, A5E02951525-03
23
You can change the [Graph Data] parameter to any of the following:
Path Flow Velocity (with Avg. Velocity for multi-path flowmeters)
Path VoS (with Average VoS for multi-path flowmeters)
Path ALC
Path Flow Rate (with Average Rate for multi-path flowmeters)
You can change the [Graph Data] parameter to any of the following for gas flowmeters:
Path VoS Difference (with average % Difference)
Path Std. Vol. Flow Rate (with Average)
You can select the [Graph Time Span] for the available range (1, 5, 15 or 30 minutes).
You can select [Auto] or [Manual] "Y" axis spanning.
Left-click the [Exit] button to leave the [Trend Graph] screen.
4.4 Diagnostics Menu
The Diagnostics menu consists of three sub-menus:
Meter Diagnostics
Stored Events
System Summary
Note
In the Meter Diagno
stics, Stored Events and System Summary, sub-menus of the
Diagnostic menu, the [Empty] and [Fault] alarms always change to red to indicate a
failure. Other alarms including [Spacing], [ZeroMatic] (for transit-time channels),
[Aeration], [Memory], [Makeup], and [Interface] change to yellow to indicate a warning.
Meter Diagnostics
The [Meter Diagnostics] screen captures current flowmeter activity in selectable time
intervals. Si-Ware displays real-time flowmeter diagnostic data and provides a Pass/Fall
indication alerting the user of marginal or poor installation conditions. This screen also
provides a useful data capture facility, which allows diagnostic data to be collected (in ".csv"
format) for later analysis.