Table 8-2 Process connections
Version FMS500
EN 1092-1 PN 6
• DN 1400 to 1200 (56" to 48")
Raised face anges
PN 10 (145 psi):
• DN 200 to 300 (8" to 12")
Flat face anges
PN 10 (145 psi):
• DN 350 to 1200 (14" to 48")
Raised face anges
PN 16 (232 psi):
• DN 50 to 300 (2" to 12")
Flat face anges
PN 16 (232 psi):
• DN 350 to 1200 (14" to 48")
Raised face anges
PN 40 (580 psi):
• DN 15 to 40 (½" to 1½")
Flat face anges
ANSI B16.5 Class 150 lb: ½" to 24"
AWWA C-207 Class D:
• 28" to 78", Flat face anges
AS4087 PN 16 (230 psi):
• DN 50 to 1200 (2" to 48")
JIS B 2220 K10 (1" to 24")
Table 8-3 Rated operating conditions
Version FMS500
Ambient temperature
Sensor -20 to +70 °C (-4 to +158 °F)
With compact transmitter FMT020 -20 to +65 °C (-4 to +149 °F)
Operating pressure [abs. bar]
1
DN 15 to 40 (½" to 1½")
0.01 to 40 bar (0.15 to 580 psi)
DN 50 to 300 (2" to 12")
2
0.03 to 20 bar (0.44 to 290 psi)
DN 350 to 1200 (14" to 48")
0.01 to 16 bar (0.15 to 232 psi)
Enclosure rating
Standard IP66/67, NEMA 4X/6
Optional IP68 and NEMA 6P (2m, 10 days) for sensor in remote design
IP68 and NEMA 6P (10m, continuously) for sensor in remote
design
Technical specications
8.1FMS500
SITRANS FMS500
46 Operating Instructions, 01/2024, A5E52677520-AA