Special applications, for example low conductivity or electrical noise
Table 8-7 Technical data, special application cables
Coil cable Special electrode cable
Basic data No. of conductors 3 3
Sqr. area 1.5 mm
2
0.25 mm
2
Shield Yes Double
Color code Brown, blue, black Brown, blue, black
Outside color Grey Grey
Ext. diameter 7.8 mm 8.1 mm
Conductor Flexible CU Flexible CU
Isolation material PVC PVC
Ambient temperature Flexible installation -5 to +70°C
(23 to 158°F)
-5 to +70°C
(23 to 158°F)
Non-exible installation -30 to +70°C
(-22 to 158°F)
-30 to +70°C
(-22 to 158°F)
Cable parameter Capacity 161.50 pF/m N/A
Inductance 0.583 μH/m N/A
L/R 43.83 þH/Ω N/A
8.3 Eect of temperature on working pressure
Eect of temperature on working pressure.
Table 8-8 Metric measures (pressure in bar)
Flange speci‐
cations
Flange rating Temperature (°C)
-5 10 50 90
Sizes DN25 to 2000
EN 1092-1 PN 10 10.0 10.0 9.7 9.4
PN 16 16.0 16.0 15.5 15.1
PN 40 40.0 40.0 38.7 37.7
ANSI B16.5 150 lb 19.7 19.7 19.3 18.0
AWWA C-207 Class D 10.3 10.3 10.3 10.3
AS 16.0 16.0 15.5 15.1
JIS 10K 14.0 14.0 14.0 14.0
Sizes DN 15 to 300
EN 1092-1 PN 10 10.0 10.0 10.0 8.2
PN 16 10.0 16.0 16.0 13.2
PN 40 40.0 40.0 38.7 37.7
ANSI B16.5 150 lb 10.0 19.7 19.7 16.2
AS 16.0 16.0 16.0 13.2
JIS 14.0 14.0 14.0
Technical specications
8.3Eect of temperature on working pressure
SITRANS FMS500
Operating Instructions, 01/2024, A5E52677520-AA 49