Cable speci󹪝cations
Only use cables with at least the same degree of protection as the sensor to install the sensor.
The line length from the cable gland to the terminals must be kept as short as possible. Line
loops in the terminal box must be avoided.
To guarantee the IP67 degree of protection, use cables with the required speci󹪝cations.
WARNING
Protective conductor terminal
The required cable is min. AGW16 or 1.5 mm
2
Cu.
WARNING
Wire insulation
For 󹪝eld wiring installation: Ensure that the national requirements of the country in which
the 󹪞owmeters are installed is met.
See also
Cable data (Page48)
5.2 Connecting the sensor
Before you start
Read the Safety notes (Page9)
Read the Basic safety notes: Installing/mounting
Read the Basic safety notes: Connecting
Connecting
5.2Connecting the sensor
SITRANS FMS500
28 Operating Instructions, 01/2024, A5E52677520-AA