3 INSTALLATION
36
SITRANS FX330
www.siemens.com/flow 08/2022 - A5E36751269-AG EN
3.8.2 Installing devices in sandwich design
Push the first bolt through the hole of both flanges.
Screw on the nuts and washers to both ends of the bolt but do not tighten them.
Install the second bolt through the holes .
Place the flow sensor between the two flanges.
Insert the gaskets between flow sensor and flanges and align them.
Check that the flange is concentric.
Install the remaining bolts, washers and nuts. Do not yet tighten the nuts.
Turn the centring ring in a counter-clockwise direction and align the device.
Check that the gaskets are concentric; they must not protrude into the pipe cross-section.
Now tighten all nuts bit by bit alternately across the diagonal.
Figure 3-14: Installation using centering ring
1 Flow sensor
2
Centering ring
3
Bolts with fixing nuts
4 Drill hole
5
Sealing