Copyright © Sigicom AB 2019
6. ISO 8569 Acceleration (It is normally recommended to use standard 16
instead of this standard)
Mechanical vibration and shock -- Measurement and evaluation of shock
and vibration effects on sensitive equipment in buildings
Level, frequency ranges: 25 m/s
2
, 5-300 Hz
Max resolution in presentation: 0.005 m/s
2
and 3 significant digits.
Threshold range 0.04 – 22 m/s
2
.
Transient file resolution: ~0.001 m/s
2
.
Note! The stated range/resolution in “acceleration” is only valid at 160Hz
because sensor element measures velocity. At lower frequencies the
range/resolution is scaled down. Above 160Hz, range/resolution is scaled
up.
7. SS 460 48 61 Komfort
Vibration och stöt – Mätning och riktvärden för bedömning av komfort i
byggnader.
Level, frequency ranges: 20 mm/s, RMS, 1-80 Hz
Filtered according to ISO 2631-2, time constant 1 s.
Max resolution in presentation: 0.005 mm/s RMS and 3 significant digits.
Threshold range 0.04 – 15 mm/s.
Transient file resolution: ~0.001 mm/s.
8. SS 460 48 61 Komfort
Vibration och stöt – Mätning och riktvärden för bedömning av komfort i
byggnader.
Level, frequency ranges: 700 mm/s
2
, RMS, 1-80 Hz
Filtered according to ISO 2631-2, time constant 1 s.
Max resolution in presentation: 0.1 mm/s
2
RMS and 3 significant digits.
Threshold range 1 – 550 mm/s
2
.
Transient file resolution: ~0.04 mm/s
2
.
9. DIN 4150-2 KB
Erschütterungen im Bauwesen – Teil 2: Einwirkungen auf Menschen in
Gebäuden.
Level, frequency ranges: 20 mm/s, RMS, 1-80 Hz
Filtered according to ISO 2631-2, time constant 125 ms.
Max resolution in presentation: 0.005 mm/s RMS and 3 significant digits.
Threshold range 0.04 – 15 mm/s.
Transient file resolution: ~0.001 mm/s.