Tables of Weighted Standards
Stan-
dard
Standard
name
Variant
Reference
frequency
Reference
level
Customer
string
S18,
S19
DIN 4150-3
Anlage
Zeile 1
<10 Hz
20 mm/s
**Z1
S18,
S19
DIN 4150-3
Anlage
Zeile 2
<10 Hz
5 mm/s
**Z2
S18,
S19
DIN 4150-3
Anlage
Zeile 3
<10 Hz
3 mm/s
**Z3
Stan-
dard
Standard
name
Variant
Reference
frequency
Reference
level
Customer
string
S28,
S29
SN640 3122a
Gele-
gentlich
<30 Hz
15 mm/s
**X1
S28,
S29
SN640 3122a
Häufig
<30 Hz
6 mm/s
**X2
S28,
S29
SN640 3122a
Perma-
nent
<30 Hz
3 mm/s
**X3
Stan-
dard
Standard
name
Variant
Reference
frequency
Reference
level
Customer
string
S40
Arrêté du
1994
-
5 - 30 Hz
10 mm/s
****
Note! For standard 40, weighting is always active.