EasyManua.ls Logo

Sigicom INFRA C12 - Standard ÖNORM S 9012 and ISO 10816-2 Details

Sigicom INFRA C12
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright © Sigicom AB 2019
58
15. ÖNORM S 9012
Beurteilung der Einwirkung von Schwingungsimmissionen des
landgebundenen Verkehrs auf den Menschen in Gebäuden ―
Schwingungen und sekundärer Luftschall .
Level, frequency ranges: 700 mm/s
2
, RMS, 1-80 Hz
Filtered according to ISO 2631-2, time constant 1 s.
Max resolution in presentation: 0.1 mm/s
2
RMS and 3 significant digits.
Threshold range 1 550 mm/s
2
.
Transient file resolution: ~0.04 mm/s
2
.
16. ISO 8569 Acceleration (Replaces standard 6, if not very small levels)
Mechanical vibration and shock -- Measurement and evaluation of shock
and vibration effects on sensitive equipment in buildings.
Level, frequency ranges: 125 m/s
2
, 5-300 Hz
Max resolution in presentation: 0.01 m/s
2
and 3 significant digits.
Threshold range 0.1 110 m/s
2
.
Transient file resolution: ~0.005 m/s
2
.
Note! The stated range/resolution in accelerationis only valid at 80Hz
because sensor element measures velocity. At lower frequencies the
range/resolution is scaled down. Above 80Hz, range/resolution is scaled
up.
17. ISO 10816-2
Mechanical vibration -- Evaluation of machine vibration by measurements
on non-rotating parts -- Part 2: Land-based steam turbines and generators
in excess of 50 MW with normal operating speeds of 1500 r/min, 1800
r/min, 3000 r/min and 3600 r/min.
Level, frequency ranges: 200 mm/s, RMS 1s, 5-500 Hz
Max resolution in presentation: 0.05 mm/s RMS, and 3 significant digits.
Threshold range 0.2 180 mm/s.
Transient file resolution: ~0.01 mm/s.

Table of Contents