EasyManua.ls Logo

Sigicom INFRA C12 - Weighted Standards Table Part 3

Sigicom INFRA C12
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright © Sigicom AB 2019
68
Stan-
dard
Standard
name
Variant
Reference
frequency
Reference
level
Customer
string
S42,
S43
IN1226
SNCF
résistant
5 10 Hz
15 mm/s
**S1
S42,
S43
IN1226
SNCF
sensible
5 10 Hz
10 mm/s
**S2
S42,
S43
IN1226
SNCF
très sensible
5 10 Hz
5 mm/s
**S3
S42,
S43
IN1226
SNCF
Plateforme
5 10 Hz
20 mm/s
**S4
S42,
S43
IN1226
Vibration
continu
résistant
<10 Hz
5 mm/s
**C1
S42,
S43
IN1226
Vibration
continu
sensible
<10 Hz
3 mm/s
**C2
S42,
S43
IN1226
Vibration
continu
très sensible
<10 Hz
2 mm/s
**C3
S42,
S43
IN1226
Vibration
continu
Plateforme
<10 Hz
5 mm/s
**C4
S42,
S43
IN1226
Vibration
transitoire
résistant
<10 Hz
8 mm/s
**I1
S42,
S43
IN1226
Vibration
transitoire
sensible
<10 Hz
6 mm/s
**I2