EasyManua.ls Logo

Signal SDS Series - Frost Program Configuration

Signal SDS Series
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SDS Series
27
Programming
The controller uses program 7 and 8 for frost control. In the [TWO-WIRE] menu, two frost
sensors (1 and 2) are available to assign to DataNodes. Sensor 1 will activate program 7
and sensor 2 will activate program 8. When the sensors are activated, all current irrigation
activity will be stopped and a loop cycle will commence on either or both programs until the
sensor deactivates.
When the FrostWatch function is enabled, the two-wire cable will switch on every 8 minutes
for a brief period to check the frost sensor status. The FrostWatch monitoring time-window
is selectable. Depending on the frost risk, the FrostWatch function can be enabled or disa-
bled at any time via the controller keypad.
FROST PROGRAM DESCRIPTION:
Scroll to the TW Data
Nodes
From the current Time
and Date display scroll
TWO WIRE
< Press Enter >
Assign DataNodes
< Press Enter >
Use numeric keys
to enter number
Enter DN No.
00 (DN N0. 112)
We will assume (1) was selected
program 7 is now a frost program
< Select Input >
Nil
Scroll to Frost
sensor (1) or (2)
From the current Time
and Date display scroll
Program Entry
< Press Enter >
Select
7 or 8
<P# WaterStn 01
00 : 00 : 00 100%
Use numeric keys to
enter run time h/m/
P# Station Delay
00 : 00 Ms
Note. See page 40,41 for configuring & downloading settings to DataNodes
ASSIGN FROST SENSORS (1) & (2) TO DATANODE:
FROST PROGRAM:
The Frost program does not
require active days to be set
P1 Day Options
NONE
< P# Mode >
Normal
P# Master Pump
Default
Select Normal or
Loop then Enter
P# Water Days
SMTWTFS SMTWTFS
< P1 Start Time 1 >
NONE
Leave the start time set to
NONE for Frost Programs
P# Total Water
00:00:00
Start Time Overlap
NONE
NONE
Start Time Overlap
Current Water %
100%
Return to Date
Time display
LOOP PROGRAMS continued
Current Water %
100%

Table of Contents