SDS Series
28
Programming
VOLUMETRIC WATERING:
As an alternative to watering by time, a set volume of water can be programmed per sta-
tion. The controller will then count pulses from the water meter assigned to that program.
Pulse resolutions supported are: 1 litre, 10 litres, 100 litres and 1000 litres. Maximum
pulse frequency is 0.25hz or 4 seconds.
Enter a program as normal
Until reaching <Option>:
<P# Option >
VOLUMETRIC
<P# Option >
TIME
P# Station Delay
00 : 00 Ms
Enter time from
keypad in m/s
P# Total Water
00000000 CM
<P# WaterStn 01
000000 Litres
Repeat for
each station
Use numeric keys to
enter total litres
Ensure the water meter pulse ratio is set in the controller, refer to Systems Settings,
Flow Meter Pulse, page 29.
Frost Watch
< Press Enter >
Use scroll < > keys to select
Enabled or Disabled
FROSTWATCH ENABLE/DISABLE:
From the current Time
and Date display scroll
SYSTEM SETTINGS
< Press Enter >
Use < > keys and
scroll to Frost Watch
Note. When the Frost Watch function is enabled the status program indicator will display
“F” (upper case). When disabled, it will display “f” (lower case)
To view the program status indicator, press [BACK] on the keypad until you reach the current
time and date. On this screen, hit the ‘0’ button.
From the current Time
and Date display scroll
SYSTEM SETTINGS
< Press Enter >
FrostTime Start
< Press Enter >
Frost Watch On
00 : 00 : 00 Am
Use numeric keys to
enter time h/m/s
FrostTime Finish
< Press Enter >
As previous, use numeric
keys to enter time h/m/s
FROSTWATCH MONITORING TIME-WINDOW: