EH-500/600 Installation Manual
Page 36
The system has two configuration banks:
1. Running Configuration – the currently active configuration. Every time Apply is
clicked, the Running Configuration is updated.
2. Startup Configuration – the configuration the system will come up with after the
next reset. This configuration may be different than the currently active
configuration (Running Configuration).
In order to save the applied configuration changes, click Save Configuration so
changes will be saved to the startup configuration. If changes are not saved to the
startup configuration, they will be lost the next time the system resets.
Save Configuration button are available for local and remote systems.
3.3.3 Rollback
A safety measure that allows recovering from system configuration changes that caused
loss of communication.
When Rollback is used, a timer runs (and restarts) whenever a management (or CLI)
command is entered. In the event that no command is entered within the timeout
period, the system automatically resets and comes up with the saved startup
configuration.
A Rollback timeout is especially recommended when configuring remote elements that
are being managed over the link.
Rollback is activated for both local and remote systems.
3.3.4 Reset
Separate buttons for local and remote reset. The system will reset and come up after
initialization (~120 seconds).
Note that any unsaved changes will be lost.
3.3.5 Copy To Remote
You can find the Copy To Remote button next to some configuration parameters or
sections. This function copies configuration to remote system based on the changes on
the local system.
Figure 3-4 Copy To-Remote icon