5.7 GAUGING
The following components on th e machine have a specific self-setting’ procedure wi th the u se o f
regulating templates (chap.1.5 "Accessories provided", page 9):
- CLAMPS
- CUTTERS
- ADAPTERS
CUTTERS do not need an automatic calibration system.
ADAPTERS provided as optionals do not require calibrating. However, if necessary adjustments can
be made to the c utting data, according to the procedures de scribed in chap.5.3.2 "ACCESSORY
FUNCTIONS FOR “COPY BY DATA CARD”", page 25.
In the circumstances listed below (see events) it may be necessary to re-set one or all of the clamps
and/or cutters that the user has in possession. This operation is semi-automatic and requires close
attention to the instructions listed below.
From the initial screen press MENU then F1 to
enable the function.
•Clamps
•Cutters
•Adapters
EVENT
MACHINE
ZEROES
CALIBRATION
CLAMP CUTTERS
Replacement of photocells
YES YES NO
Electronic board replacement
YES YES NO
Replacement of sensors
YES YES NO
Replacement of the cutter shaft
YES YES NO
Replacement of the ball screws
YES YES NO
Clamp V100 replacement
(with a new one of the same type)
NO NO NO
Re-sharpening of existing cutter and/or cutter
replacement (with a new one of the same type)
NO YES YES
Installation of optional clamps
NO YES
(if applicable)
NO