52 Copyright S ilca 2010
5.9 OPTIONS
From the initial screen, press MENU then F3 to enable the function.
There are 4 machine option windows that are selected by pressing F4.
ATTENTION: Hold down F4 to take the machine back to its initial state (with the original parameters set
by Silca).
Machine Parameters/Options that can be forced from the original factory setting:
Rapid speed: 4000
Cutting speed: 400
Reading speed: 350
Minimum distance from stop: 50
Stop adjustment enabling: 0 --> Disabled
Parameter X stop adjustment: 0
Parameter Y stop adjustment: 300
Parameter H stop adjustment: 370
Parameter L stop adjustment: 0
Measuring unit: 0
Date format: 0 --> GG/MM/AA
Time format: 0 --> 0-24
Keyboard Inversion: 0 --> Disabled
Cutting check: 1 --> Enabled
Rapid menu for PC queue: 0 --> Disabled
Machine Options [page 1/4]
The display shows: Preferences
Current language:
use the arrow key s (rh/lh) to select the meas uring unit
required (mm = millimetres, inches) then press ENTER to
confirm.
Measuring unit:
use the arrow key s (rh/lh) to select the meas uring unit
required (mm = millimetres, inches) then press ENTER to
confirm.
Key pad inversion:
this function is normally disabled. Use the arrow keys (rh/
lh) to select enabled or disabled then pres s ENTER to
confirm.
The operation is used to invert the function of the
alphanumerical keys.
With “Key pad inversion” disabled:
• To digit number 3 press 3/K
• To digit the letter K: press SHIFT + 3/K
With “Key pad inversion” enabled:
• To digit number 3: press SHIFT + 3/K
• To digit the letter K: press 3/K
Cutting check:
This option is used to enable and disable control of the combinations entered on the cutting card, by pressing
SHIFT + [up arrow].
Default is enabled, i.e. there is constant control that the c ombination entered is compatible with the cutting
path.
Such control has certain rules that prevent the operator from creating keys which are not guaranteed to work.