Telemetry
This section deals with all of the various messages that can be overlaid onto the video display in order to assist the
operator.
Disable OSD - disables display of fixed OSD telemetry messages such as the camera text and date/time. This option does not
hide messages that are shown in response to user actions.
Camera text - This allows the camera-name text to be edited (Up to xx characters).
Camera text X and Camera text Y - These control the position of the camera-name text on the screen. Setting either the X or
Y value to 0 will hide the camera text.
>Cardinal text - This opens a submenu for editing the cardinal position texts. There are 8 text strings associated with the
North, North-East, East, South-East, South, South-West, West and North-West compass sectors.
Cardinal text X and Cardinal text Y - These control the position of the cardinal text labels on the screen. Setting either the X
or Y value to 0 will hide the text.
Compass display - The compass display shows the camera's Pan and Tilt co-ordinate values. These can be displayed as
either ‘PAN’, ‘TILT’ or ‘BOTH’.
Compass text X and Compass text Y - These control the position of the co-ordinate text on the screen. Setting either the X or
Y value to 0 will hide the display.
Datetime display - The time can be displayed as ‘TIME’ or ‘DATE’. The ‘DATE’ display includes the time.
Datetime text X and Datetime text Y - These control the position of the time text on the screen. Setting either the X or Y value
to 0 will hide the text.
Prepos text - This allows the text label shown beside the Preset position numbers to be edited, (default: Prepos n).
Prepos text X and Prepos text Y - These control the position of the Preset position text on the screen. Setting either the X or
Y value to 0 will hide the text.
Environmental X and Environmental Y - These control the position of the internal (PCB) Temperature/Humidity information
on the screen. Setting either the X or Y value to 0 will hide the text.
Silent Sentinel Oculus
Version n.nnn (xxxx) xx
SN: FFFFFFFF POST: 000000000
Disable OSD Off
Camera text Text1
Camera text X 2
Camera text Y 1
>Cardinal text
Cardinal text X 12
Cardinal text Y 0
Compass display TILT
Compass text X 15
Compass text Y 0
Datetime display TIME
Datetime X 2
Datetime Y 0
Prepos text Prepos
Prepos text X 15
Prepos text Y 0
Environmental X 24
Environmental Y 14
Exit menu

Other manuals for Silent Sentinel Oculus