The RingCast was able to address
all locking devices.
The RingCast could not be closed.
Possible causes (see also
Central
output router [}132]
):
One or more RouterNodes have
not received the data packet.
One or more RouterNodes have
not reached one or more
LockNodes.
Ethernet connection to one or
more RouterNodes is interrupted.
The RouterNodes could have
received the data packet
wirelessly, but could no longer
return their input
acknowledgements due to the
interrupted Ethernet connection.
1. Check the reachability of the
RouterNodes mentioned (see
RouterNodes [}174]
und
Test
reachability (LSM) [}177]
).
2. Check the reachability of the
LockNodes (see
LockNodes
[}176]
und
Test reachability
(LSM) [}177]
).
3. Check the last responses of the
LockNodes (see
IO Status and
LockNode responsiveness
[}179]
).
5.4.5.9 Deleting RingCast
ü WaveNet Manager opened via LSM (see
Best Practice: From the LSM
software [}37]
)
ü RouterNodes and LockNodes connected to power supply.
1. In the overview, right-click on the top entry of the RingCast you want to
delete.
9 The window "Edit radio domains" opens.
WaveNet (Manual)
5. WaveNet Manager
139 / 210