Transducer Installation
Example: Medium sized transducer without
clamping ring
The illustration below shows a transducer blister designed for a
medium sized transducers. The same blister design principles
apply. Note that the transducer is mounted without a clamping
ring, which makes it necessary to use a different mounting ring
design.
A
B
C
H
F
E
E
G
D
I
(CD017010E)
(A) = Streamlined blister
(B) = Mounting ring
(C) = Bolt
(D) = Self-locking threads
(E) = Air outlet
(F) = Forward
(G) = Transducer cable
(H) = Transducer
Note that the transducer cable must be provided with a cable loop
inside the blister. Observe the vertical forward edge of the blister.
This will guide the water to each side of the blister.
304699/A 123