EasyManua.ls Logo

Simrad ES60 - INSTALLATION REV A - Single Beam Transducer to Split Beam Transceiver

Simrad ES60 - INSTALLATION REV A
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cable layout
Single beam transducer to split beam
transceiver
This is the termination of the transducer cable from a single
frequency, single beam transducer to the socket on a split beam
General Purpose Transceiver Unit (GPT). The other end of the
cable is permanently xed to the transducer.
M
E
F
J
H
D
C
K
L
A
B
N
Transducer
cable
E
A
B
C
D
H
J
F
Junction Box (1:1)
(Optional)
GPT Transducer
socket
Screen Connect to plug housing
W802-9
Rev.A
Single frequency, single beam, to split beam transceiver, termination
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the transducer cable in a steel conduit.
Related topics
Cable splicing on page 140
Steel conduit on page 140
GPT Transducer plug connection on page 105
304699/A 73

Table of Contents