Cable layout
GPT trigger / synchronisation
This cable is used t o connect the General Purpose Transceiver
(GPT) to an e xternal system for synchronisation purposes. It
connects to the 25–pin D -sub connector on the front side of the
GPT.
25
GPT
25-pin D-sub connector
24
13
12
TrigOut(+)
TrigOut(-)
TrigIn(+)
TrigIn(-)
SIMRAD
GPT
25
14
1
13
Auxiliary
connector
(female)
The cable screen is connected to the plug house.
W620B
Rev.D
Synchronisation / External trigger
Conductors: 2 x 2 x 0.22 mm2
Screen: Braided pairs and overall braided
Voltage: 60 V
Maximum diameter: Dened by the plugs