EasyManua.ls Logo

Simrad ES60 - INSTALLATION REV A - Cable between SH;SP Sonar and Echo Sounder

Simrad ES60 - INSTALLATION REV A
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cable layout
Cable between SH/SP sonar and echo
sounder
This cable is used to provide a two-way communication between
the echo sounder and a SP60, SP70, SP90, SH40 or SH80 sonar
system.
W620I
Rev.A
Communication between sonar (SP/SH) and echo sounder
1
55
3
3
2
2
4
Receive (Rx-)
Transmit (Tx+)
Transmit (Tx-)
Ground
Receive (Rx+)
Receive (Rx)
Transmit (Tx)
Ground
Sonar Interface Unit
TB1 - TB7
Suitable serial line
connector on echo
sounder computer
TB4
TB1-3
TB5-7
The Sonar Interface Unit is equipped
with seven serial line communication ports.
TB1 = COM2
TB3 = COM4
TB5 = COM6
TB7 = COM8
TB2 = COM3
TB4 = COM5
TB6 = COM7
Conductors: 9 x 2 x 0.5 mm2
Screen: Screened twisted pairs and overall braided
Voltage: 60 V
Maximum diameter: Limited by the plugs
304699/A 67