Cable layout
Single beam, high power transducer
This is the termination of the transducer cable from a single
frequency, single beam transducer to the t ransducer socket on the
General Purpose Transceiver Unit (GPT). The other end of the
cable is permanently xed to the transducer.
High power output (more than 1 kW) is achieved when the GPT
is equipped with four transmitter boards
M
E
F
J
H
D
C
K
L
A
B
N
Transducer
cable
E
A
B
C
D
H
J
F
Junction Box (1:1)
(Optional)
GPT Transducer
socket
Screen Connect to plug housing
W802-2
Rev.E
Single frequency, single beam, high power termination
Drain wire
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the transducer cable in a steel conduit.
Related topics
Cable splicing on page 140
Steel conduit on page 140
GPT Transducer plug connection on page 105