Transducer Installation
Example
The t ransducer shown in the gure below is mounted inside the
tank behind a strong acoustic window which could be made of
polycarbonate. The tank is lled with oil.
(CD017012B)
B
A
C
G
D
E
F
(A) = Steel tank
(B) = Oil
(C) = Acoustic window
(D) = Cable service loop
(E) = Stufng tube
(F) = Cable in steel conduit
(G) = Oil inlet
304699/A 131