Preventive maintenance | SRT LAN radar sensor S-band down-mast Service Manual
7 Remove the protective transparent cover
8 Remove the two nuts securing the magnetron cables, taking note of their position
9 Remove the two plastic caps at the top of the SRT LAN down-mast. See “SRT LAN down-mast
transceiver on page 8
10 From the external side, unscrew and remove the two spacers securing the magnetron (B)
11 Remove the four screws securing the magnetron (C)
12 Remove the magnetron
A
B
C
C
13 Before fitting the new magnetron spread a layer of silicone compound on the contact surface
to improve the magnetrons heat dissipation
14 In order to install the new magnetron, perform the removal steps in reverse order
15 On the R5000 PSU, switch the power switch to the ON position and remove the card reading
WORK IN PROGRESS - DO NOT SWITCH ON
16 On the electric switchboard, set the radar main breaker to ON and remove the card reading
WORK IN PROGRESS - DO NOT SWITCH ON
17 Wait 30 minutes before switching on the radar
Software
There is a timer that counts the number of hours the magnetron has been transmitting. The
system gives a warning when the magnetron is close to the end of its expected lifetime.
From the radar data dialog, it is possible to view the hour count and the magnetron end of life
status (which reports OK or FAIL). When the magnetron is replaced, the timer should be reset.
Access the Installation dialog, and select the Magnetron timers reset option.