| 37
Fault repair | SRT LAN radar sensor S-band down-mast Service Manual
14. In order to install the new brushless motor, perform the removal steps in reverse order
15. Switch the safety switch to the ON position
16. On the R5000 PSU, switch the power switch to the ON position and remove the card reading
WORK IN PROGRESS - DO NOT SWITCH ON
17. On the electric switchboard, set the radar main breaker to ON and remove the card reading
WORK IN PROGRESS - DO NOT SWITCH ON
Gearbox with driving gear replacement
1. Follow the steps for removing the brushless motor. See “Brushless motor replacement” on
page 36
2. Remove the gearbox with the driving gear
3. In order to install the new gearbox with the driving gear perform the removal steps in reverse
order
4. Switch the safety switch to the ON position
5. On the R5000 PSU, switch the power switch to the ON position and remove the card reading
WORK IN PROGRESS - DO NOT SWITCH ON
6. On the electric switchboard, set the radar main breaker to ON and remove the card reading
WORK IN PROGRESS - DO NOT SWITCH ON
Performance monitor arm replacement
1. On the electric switchboard, switch OFF the radar main breaker and place a card reading
WORK IN PROGRESS - DO NOT SWITCH ON
2. On the R5000 PSU, switch the power switch to the OFF position and place a card reading
WORK IN PROGRESS - DO NOT SWITCH ON
3. Switch the safety switch to the OFF position
4. Remove the four screws securing the performance monitor arm (A)
5. Remove the Performance monitor arm (B)
6. In order to install the new Performance monitor arm, perform the removal steps in reverse
order
7. Switch the safety switch to the ON position
8. On the R5000 PSU, switch the power switch to the ON position and remove the card reading
WORK IN PROGRESS - DO NOT SWITCH ON
9. On the electric switchboard, set the radar main breaker to ON and remove the card reading
WORK IN PROGRESS - DO NOT SWITCH ON
Rotating joint replacement
1. On the electric switchboard, switch OFF the radar main breaker and place a card reading
WORK IN PROGRESS - DO NOT SWITCH ON
2. On the R5000 PSU, switch the power switch to the OFF position and place a card reading
WORK IN PROGRESS - DO NOT SWITCH ON