22 |
Diagnostics | SRT LAN radar sensor S-band down-mast Service Manual
Checking the radar sensor
Certain types of checks can be performed after opening the SRT LAN down-mast transceiver’s
cover.
! Warning: When the cover of the SRT LAN down-mast transceiver is opened,
the first safety switch called Interlock is activated. For extra safety, this spring
switch which opens at the moment the panel is removed interrupts the
transmission that disables the 700 V High Voltage that the SRT MOS PCB
requires. To carry out a check simulating a closed panel, pull it towards the
outside.
Semi-operative controls
Pos. Code (Ref.
ASSY)
Type Function
Structure
Down-mast S1 Interlock
TXRX cover interlock switch for
disabling the High Voltage generation
and interrupts the transmission
SRT control S1 10
Position rotary
switch
It selects the TXRX unit operation
mode as follow:
Pos. Function
0 SRT under external control 1
1 SRT under external control 2
2 SRT in local standby
3 The SRT works independently
from the console with short
pulses
4 The SRT works independently
from the console with
medium pulses
5 The SRT works independently
from the console with long
pulses
6 SRT in local with long pulse
and performance monitor
with auto tuning and antenna
rotation
7 Standby mode
8 Standby mode
9 Service mode Long pulse.
Performance monitor ON.
Autotune. Antenna rotating