22
409977/B
7Makesurethattheunithasbeenidentiedwiththerelevantproductlabel(s),and
thatonelabelincludesthepartandserialnumbers.
Result
Requirements
Results
TheOperatingPaneliscorrectlyinstalledwitheasyaccessformaintenance
andreplacementofparts.
TheOperatingPanelisfreefromscratches,dentsorotherphysicaldamage.
FreeaccesstoalltheconnectorsontheOperatingPanelareprovided.
Allcablesareproperlymountedwithenoughslack.
TheOperatingPanelisproperlygrounded.
Dateandsignature:
VisualinspectionoftheTransceiverUnit
AvisualinspectionoftheTransceiverUnitisrequiredtoverifythattheunithasnotbeen
physicallydamagedduringtheinstallation.
Prerequisites
TheSU90hasbeensetupwithitshardwareunitsconnectedasspeciedintheSU90
Installationmanual.TheSU90isturnedoff.Youneedthefollowingequipment:
•Multimeter
Procedure
1Makesurethattheunit’sserialnumberhasbeenrecordedinthelistofhardware
items.
2MakesurethattheTransceiverUnitisinstalledinthecorrectlocation,andthatitis
suitablyorientedforeasymaintenanceandreplacementofparts.
3MakesurethattheTransceiverUnitisfullypopulatedwithallcircuitboardsand
modulesmounted.
4Makesurethatthephysicalinstallationoftheunithasbeencompleted.
aMakesurethatthecabinetdoorcanbefullyopenedforunrestrictedaccess.
bMakesurethatamplespaceisprovidedaroundtheunittoallowfor
maintenanceandreplacementofparts.
cMakesurethatthebolts,screwsorstudsholdingtheunitareofthecorrectsize.
dMakesurethatthecorrectatandshake-proofwashershavebeenused.
eMakesurethatallnutshavebeentightenedproperly.
SimradSU90HarbourAcceptanceTest